Home > Products > Components for Electrics > Circuit Breaker > ZW30-40.5 Outdoor HV Vacuum Circuit Breaker
ZW30-40.5 Outdoor HV Vacuum Circuit Breaker

ZW30-40.5 Outdoor HV Vacuum Circuit Breaker

ZW30-40.5 Outdoor HV Vacuum Circuit Breaker ZW30-40.5 Outdoor HV Vacuum Circuit Breaker is available in power T&D system with rated voltage of 35kV, rated current of 1600A, AC three phase and 50 Hz. It could be used in industrial enterprises and mines, power plant and substation for protection and controlling, as well as inter connection circuit breaker. This is also available in places for frequent operations.

Send Inquiry

Product Description

ZW30-40.5 Outdoor HV Vacuum Circuit Breaker


1.  Product Introduction

ZW30-40.5 Outdoor HV Vacuum Circuit Breaker accord with the requirement of GB 1984-89 'AC HV circuit breaker', IEC56 'HV AC circuit breaker' and JB3385-1996 '3.6-40.5kV indoor AC HV vacuum circuit breaker'.


2. Main technical data ofZW30-40.5 Outdoor HV Vacuum Circuit Breaker

Table1

No.

Name

Unit

Parameter

1

Rated voltage

kV

40.5

2

Rated

insulation

level

Rated 1min

power frequency

withstand voltage

Dry test (break point, phase to phase,

95

phase-to-earth)

80

Lightning impulse withstand voltage(peak)

185

3

Rated current

A

2000

4

Rated short-circuit breaking current

kA

31.5

5

Rated short-circuit making current

kA

80

6

Rated operation sequence

0-0.3s-CO**-180s-CO**

7

Rated out-of-phase breaking current

kA

8

8

Rated single capacitor bank breaking current

A

630

9

Rated duration of short circuit

s

4

10

Rated short-circuit breaking current break times

times

20

11

Arcing time

ms

<20

12

Full breaking time

ms

≤85

13

Mechanical life (CO)

times

10000

14

Rated gas

Insolating

pressure

Adopt TD-40.5W/2000-31.5(K) Vacuum arc extinguish room, filled with SF6 gas

Mpa

0.02(20°C)

Adopt TD-40.5W/2000-31.5(K) Vacuum arc extinguish room, filled with dry air and high pure nitrogen.

15

Annual gas leakage rate

%

≤1

16

Vacuum arc Extinguish

Room Vacuum degree

New ex-work vacuum arc extinguish room

Pa

≤1.33X10􀄨

20 years of storage

<6.6X10􀄧

Note: Insulation level of porcelain knob and tube is tested as per height o * f above sea level 3000m.

Three values are 100kV, 120kV, 230kV.

 CO make-break time is 0.1s.


Table 2

No.

Name

Unit

Parameter

1

Contact journey

mm


20±1

2

Super journey

4±1

3

Contact allowable abrasion thickness

3

4

Average opening speed (before contacting cushion)

m/s


1.85~2.15

Measured at base shaft

5

Average closing speed (full journey is 20mm)

0.7~1.0

6

Contact closing bounce time

m/s

≤3

7

3 phase opening insimultaneity

≤2

8

3 phase opening insimultaneity

≤2

9

Closing time

45~100

10

Opening time

33~65

11

Each electric circuit resistance

μΩ

≤40

12

Opening contact rebound value

m/s

3

13

Phase to phase central distance

750±1


3.Service ambient condition ofZW30-40.5 Outdoor HV Vacuum Circuit Breaker

a. Altitude height: ≤3000m;

b. Ambient temperature: -40C~+40°C;

c. Ambient air may polluted with dust, smoke, corrosion gas, steam and salty fog. The pollution grade can't

beyond II grade of GB/T5582 when altitude is in 3000m, pollution grade may reach IV grade of GB/T5582 when

altitude ≤1000m;

d. Wind speed: ≤34m/s (correspond to exterior of column 700Pa )

e. Vibration and earthquake come from out of the product may ignored.

F. Other special service condition may settled by the user and manufacture.


4. Maintenance and repair for ZW30-40.5 Outdoor HV Vacuum Circuit Breaker

a. ZW30-40.5 Outdoor HV Vacuum Circuit Breaker and operation mechanism should be checked and lubricated termly to avoid rusting.

b. Check if screws and nuts of each part are flexible every 2000 times operation, if it is flexible, it should be screwed down in time.

c. Vacuum arc extinguish room enclosure should not stand with the force beyond 1000N and obvious pull force can't effected when & after installation.

d. Prohibit firm object (as tool) to impact insulation porcelain tube to avoid gas leakage and effecting insulation.


 

 

Hot Tags: ZW30-40.5 Outdoor HV Vacuum Circuit Breaker, China, Manufacturers, Suppliers, Factory, Made in China

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you within 24 hours.