Home > Products > Components for Electrics > Circuit Breaker > VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker
VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker
  • Air ProVT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker

VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker

VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker is indoor switchgear, used for three-phase 50Hz, 35KV electric power system. It is a control and protective unit, applied in electric utility of industrial and mining company, power station and substation.

Send Inquiry

Product Description

1. Introduction of VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker


VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker is indoor switchgear, used for three-phase 50Hz, 35KV electric power system. It is a control and protective unit, applied in electric utility of industrial and mining company, power station and substation. Because of its special superiority, it is also suitable for the occasions requiring frequent operation rated working voltage or repeatedly break short-circuit current. It has reliable interlock function, and not only serves as handcart unit, but also as fixed unit.

 

 

2. Parameter (Specification) of VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker

 

Rated voltage

40.5kV

Rated frequency

50Hz

Rated lighting impulse withstand voltage(between phases,phase to earth) /isolated fracture

185

Rated 1min power withstand voltage(between phases,phase to earth) /isolated fracture

95

Rated operation sequence

O-0.3s-CO-180s-CO

Rated current (A)

630,1250

1250~3150

1250~3150

3150,4000

 

Mechanical Characteristics Parameters of CB

Name

Unit

Data

Clearance between Open contacts

mm

18±1

Over-travel

6±1

Three-phase opening & closing non-synchronous

ms

≤2

Bounce time of closing contact

ms

≤3

Contact pressure of Closing Contact

Opening

 

N

20KA,25KA.31.5KA

Closing

2000±200 2700±200 3100±200

Average opening speed

m/s

1.4~1.8

Average closing speed.

0.5~0.9

 

 

3. Service condition of VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker


1 .Ambient temperature:-40°C~+40°C.

2. Hight :≤2000 meters.

3 .Earthquake intensity: Below level 8.

4.

 

Humidity condition

Daily mean

relative humidity

≤95%

Daily mean

vapour pressure

≤2.2×10-3MPa

Monthly mean

relative humidity

≤90%

Monthly mean

vapour pressure

≤1.8×10-3MPa

5. No fire, water drop, explosion, serious filthy, chemical corrosion and violent vibration of places.

6. Environment humidity: month average relative humidity ≤90%, daily average relative humidity ≤95%.

7. Customers have other special requirements, can be in order to put forward, our company can offer most satisfied.

 

 

 

 

Hot Tags: VT 19-40.5 EP Indoor HV AC Resin Vacuum Circuit Breaker, China, Manufacturers, Suppliers, Factory, Made in China