Home > Products > Components for Electrics > Circuit Breaker > VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker
VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker
  • Air ProVT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker

VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker

VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker used as control and protection department in the mining company 、power factory and substation. Because of its special advantages, it is also suitable for the site which frequently operation under rated current or multiple breaking short-circuit current.

Send Inquiry

Product Description

1.Introduction Of VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker


VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker is used in three-phase AC electric system of 50HZ、12kV. It is used as control and protection department in the mining company 、power factory and substation

 

 

2.Parameter (Specification) of VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker

 

The main parameter of VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker

Rated voltage

24kV

Rated frequency

50Hz

Rated lighting impulse withstand voltage

125kV

Rated 1 min power frequency withstand voltage

65kV

Rated operation sequence

O-0.3s-CO-180s-CO

Rated current (A)

6301250

1250160020002500

Rated short circuit breaking current (r.m.s, kA)

20/25

31.5

Rated short circuit making current (peak value, kA)

50/63

80

Rated short time withstand current/short circuit continuous time (kA/s)

2025/4

31.5/4

Rated peak value withstand current (kA)

50/63

80

Breaking times of rated short circuit(times)

30

Mechanical duration (times0

20000

Weight (kg)

Fixed type

250

Truck type

350

 

 

Mechanical characteristic of 24KV VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker

Name

Unit

Data

Distance of contact terminal

mm

12±1

Over-travel

4±1

Three-phase opening & closing asynchronous

ms

2

Tripping time of closing contact terminal

ms

≤2

Closing & opening time

Opening

ms

≤50

Closing

≤70

Average opening speed(after opening 6mm)

m/s

1.4±0.3

Average closing speed(after closing 6mm)

0.8±0.2

 

 

4. Service condition of VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker


▲Normal condition
Ambient temperature +40℃~-15℃
Ambient humidity Daily average relative humidity ≤95%
Daily average stream pressure ≤2.2ⅹ10-3MPa
Monthly average relative humidity ≤90%
Monthly average stream pressure ≤1.8ⅹ10-3Mpa
Elevation ≤1000m
Degree of earthquake <8
The site has no water、no fire goods and explosion goods、no chemical goods and serious quake.

▲Special condition
If user has some special requirement, please negotiate by manufacture and user.

 

 

5. Qualification Of VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker


VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker is identified by some national standards and international relative standards, such as GB1984、GB/T11022、DL/T403 and IEC62271, etc. It has reliable lockage, used as truck department or fixed installation department.

 

 

 

 

Hot Tags: VT 19-24 EP Indoor HV AC Resin Vacuum Circuit Breaker, China, Manufacturers, Suppliers, Factory, Made in China

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you within 24 hours.