ZN12-40.5 Type indoor AC high voltage vacuum circuit breaker is the introduction of Germany's Siemens technology developed on the basis of products, mainly used in 40.5kV, within the current system of AC 50Hz indoor switchgear, and other products comply with IEC56 standards.
ZN12-40.5 Type indoor AC high voltage vacuum circuit breaker
1. Product Introduction
ZN12-40.5 Type
indoor AC high voltage vacuum circuit breaker is based on retention ZN12-12 series of spring
mechanism with high reliability a bit on the small domestic use of longitudinal
magnetic field vacuum interrupter 90's newly developed product is small,
reliable performance, installation flexibility and other advantages.
Meanwhile, in order to suit different requirements of the switchgear,
developed 350,400 / 460mm from the three different phases of products to meet
the needs of different users. Product is suitable for frequent operation at
rated parameters, and breaking several fault short circuit current. ZN12-40.5 Type
indoor AC high voltage vacuum circuit breaker is applicable to both handcart
switchgear, also applies to fixed switchgear.
2.Product Parameter (Specification) of ZN12-40.5 Type indoor AC high voltage vacuum circuit breaker
No. |
Item |
Unit |
Parameters |
|
1 |
Rated voltage |
kV |
40.5 |
|
2 |
Rated current |
A |
1250,1600,2000,2500 |
|
3 |
Rated short circuit breaking current |
kA |
25 |
31.5 |
4 |
Dynamic stability current |
kA |
63 |
80 |
5 |
Thermal stability current |
kA |
25 |
31.5 |
6 |
Rated short-circuit current |
kA |
63 |
80 |
7 |
Rated short circuit breaking times |
time |
30 |
30 |
8 |
Sequence of operations |
|
|
|
9 |
Lightning impulse withstand voltage |
kV |
O-0.3S-CO-180S-CO |
|
10 |
Rated short-duration power frequency withstand voltage (1min) |
kV |
185 |
|
11 |
Closing time |
ms |
95 |
|
12 |
Opening time |
ms |
=< 90 |
|
13 |
Charging time |
s |
=< 70 |
|
14 |
Mechanical life |
time |
=< 15 |
|
15 |
Rated current breaking times |
time |
10000 |
|
16 |
Charging motor rated power |
W |
10000 |
|
17 |
Charging motor rated voltage |
V |
275 |
|
18 |
Sub-gate solenoid rated voltage |
V |
110 220 |
|
19 |
Sub-gate solenoid rated resistance |
Ω |
DC110 DC220 |
|
20 |
Sub-gate solenoid rated current |
A |
57.7 247 |
|
21 |
Over-current release rated current |
A |
DC1.91 DC0.89 |
|
22 |
Auxiliary switch rated current |
A |
5 |
3. Type meaning of ZN12-40.5 Type indoor
AC high voltage vacuum circuit breaker
Z N 12 - 40.5 / 0- 0
Z: vacuum circuit breaker
N: Indoor
12: No. Product Design
40.5: Rated voltage
0: Rated current
0: Rated short circuit breaking current
4. Structure Introduction of ZN12-40.5 Type indoor AC high voltage vacuum circuit breaker
ZN12-40.5 Type indoor AC high voltage vacuum circuit breaker before
and after leading electrical circuit with the actuator arrangement, the circuit
breaker operating mechanism for the special spring mechanism, while retaining
the original mechanism ZN12 (introduction of Siemens technology) mechanism
while the merits of the relevant parts shall be suitably modified.
Main circuit selected advanced AMF vacuum interrupters, circuit breakers
small, reliable performance. Mainly by the overall structure of the vacuum
interrupter, operating mechanism and supporting parts in the front end of the
fixed mechanism box six insulators, three up and down through a vacuum
interrupter appear fixed on the insulator, at the outlet is equipped with soft
connection, flexible connection conductive vacuum interrupter chamber is connected
to the folder.
At the bottom of the movable conductive rod is mounted bearings,
spherical plain bearings through the shaft pin with the lower outlet end of the
crank arm connected to the actuator shaft by three insulated rod to the torque
transmitted to the conductive bars open and close the switch to complete the
action.
5. Ordering Information for ZN12-40.5 Type
indoor AC high voltage vacuum circuit breaker
1. The name of the circuit breaker, model, size and number of orders
2. The circuit breakers
rated voltage, rated current and rated short-circuit breaking current
3. Optional element program
4. Rated operating voltage
5. Spare, the name
and quantity of spare parts
6. If there are other special customer requirements, when ordering