ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station) is used in solar power supply system of 50Hz, 10kV-35/0.27kV-0.4kV, the rated capacity of transformer is 630~1600kVA, which is specially used in power supply and distribution in solar power plant.
1. Introduction of ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station)
ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station) is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments. It transforms the 0.27kV-0.4kV voltage produced by solar power sets and inverter into 10kV or 35Kv, and output the electricity through 35KV cable line, which is the ideal equipment in solar power system.
2. Main parameter of ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station)
System voltage: 35kV, 10kV
Max. service voltage of HV side: 40.5kV, 12kV
Rated voltage of HV side: 35kV, 36.75kV, 38.5kV, 10.5kV
Rated voltage of LV side: 0.27kV, 0.3kV, 0.315kV, 0.4kV
4.2 Rated capacity: 630kVA-1600kVA
4.3 HV tapping range: +5% or + 2ⅹ2.5%
4.4 Connecting symbol: Dyn11 or Yyn0
4.5 Rated frequency: 50Hz
3. Features of ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station)
a. Full-sealed, safe and reliable, the product adopts 10kV or 35kV energy-saving transformer technology with reasonable structure and high reliability.
b. With advantages of small volume, compact structure, light weight and easy installation.
c. With relatively high over-load capacity.
d. The body adopts special technology to process, so it is with excellent anti-corrosion capability, which can effectively prevent the corrosion from wind, sand, salt and fog, etc.
e. Kinds of protective measures are adopted in high and low sides, which ensure the long-term safe operation.
4.Executive standards for ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station)
JB/T10217-2000 Combined transformer
GB4208-2003 Protection degree of enclosure (IP code) (eqv IEC 60529:2001)
GB1094.1-1996 General rules of Power transformer
GB1094.2-1996 Temperature rise of power transformer
GB1094.3-2003 Power transformer Chapter 3: Insulation level/ insulation test and outer-insulation air clearance
GB1094.5-2003 Power transformer Chapter 5: Short-circuit withstand capability
GB/T6451-199 Requirements on technical parameters of oil-immersed power transformer
GB3804-1990 3-63kV AC HV load switch
GB/T15166.2-1994 AC HV fuse current-limiting fuse
5. FAQ for ZGS-Z.F.(Z.G) 35 KV Wind Power and Photovoltaic Power Combined Transformer (American Box Station)
1) How do you pack the equipment?
By wooden case
2) What is your products standardization?
IEC and GB
3) How many years have your company made this kind of equipment?
More than 20years
4) What is the terms of payment?
L/C, T/T
5) What is your MOQ?
1set
6) How long is your delivery time?
60 working days