ZGS-Z 12 KV Series Combined Transformer (American Box Station) is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments.
1.Introduction of ZGS-Z 12 KV Series Combined Transformer (American Box Station)
ZGS-Z 12 KV Series Combined Transformer (American Box Station) is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments. ZGS-Z 12 KV Series Combined Transformer (American Box Station) transforms the 0.69kV voltage produced by wind power motor into 35kV,and output the electricity through 35KV cable circuit, which is the ideal equipment in wind power complete set equipment.
2. Product Parameter (Specification) of ZGS-Z 12 KV Series Combined Transformer (American Box Station)
Table 1
|
Name |
Unit |
Parameter |
||
1 |
Rated voltage |
KV |
12 |
||
2 |
Rated current |
A |
315 |
630 |
|
3 |
Rated frequency |
Hz |
50 |
||
4 |
Rated short-circuit withstand current |
kA/2s |
12.5 |
20 |
|
5 |
Rated peak withstand current |
kA |
31.5 |
50 |
|
6 |
Mechanical endurance |
times |
>2000 |
||
7 |
1 min power withstand voltage (phase-to-phase, phase-to-earth) |
kV |
42 |
||
8 |
Lightning impulse level (phase-to-phase, phase-to-earth) |
KV |
75 |
Parameter of 12kV fuse for ZGS-Z 12KV Series Combined Transformer (American Box Station)
Table 2
Rated voltage |
Fuse rated current A |
Rated Max. breaking current kA |
Remark |
15.5 |
63, 80,100,125,150 |
50 |
off line back-up type |
15.5 |
6.3,10,16,25,40,63,100,140 |
2.5 |
Plug -in |
Parameter of lightning arrester for ZGS-Z 12KV Series Combined Transformer (American Box Station)
Table 3
Rated voltage |
Continuous operating voltage |
DC reference voltage (1mA) |
Nominal discharging current |
Nominal discharging current residual |
2ms square-wave current withstand value |
17kV |
13.6kV |
≥24kV |
5kA(peak value) |
≤45kV (peak value) |
≥250A(peak value) |
3. Normal ambient conditions for ZGS-Z 12 KV Series Combined Transformer (American Box Station)
Altitude shall be within 2000m
Ambient temperature range shall be : -40ºC~+40ºC
Outdoor wind speed shall not exceeds 35m/s
Relative humidity: daily average value shall not exceed 95%, monthly average value 90%
Installation site: indoor
Service environment : installed in sites with no fire or explosion danger, serious fifth, chemical corrosion and fierce vibration.
When transcend the above normal ambient conditions for service, users can negotiate with us to solve.