SIVACON 8PT Series LV Switchgear (switchgear for short) is a latest international low voltage devices with imported Siemens's latest manufacturing technology and its advanced switch and automation technology.
1.Product Introduction
SIVACON 8PT Series LV Switchgear (switchgear for short) is a latest international low voltage devices with imported Siemens's latest manufacturing technology and its advanced switch and automation technology. With its standard structure in construction and industry, it can perfectly mounted components not onIy from Siemens but also from other factories. It can be used in power distribution system with various capacity and maximum rated current to 7400A application of fixed setting or withdrawable technology
2. Product Parameter (Specification) of SIVACON 8PT Series LV Switchgear
Rated insulation voltage |
690V |
|
Rated operating voltage |
380(400)v |
|
Rated frequency |
50Hz |
|
Rated impulse withstand voltage |
12KV |
|
Rated current |
Rated current of horizontal busbar |
Max to 4000A |
Rated current of vertical busbar in PC switchgear |
Max to 4000A |
|
Rated current of vertical busbar in MCC switchgear |
1000A |
|
Main busbar |
Rated short time withstand current |
10/50/80kA |
Rated peak withstand current |
20/105/176kA |
|
Vertical busbar |
Rated short time withstand current |
10/50/65/80kA |
Rated peak withstand current |
20/105/143/176kA |
|
Degrees of protection |
IP20-IP54 |
|
Dimensions (Width x Depth x Height) |
Width:2200mm Height:400/600/800/1000/1200/1400mm Depth:600/800/1000mm |
3. Product Feature of SIVACON 8PT Series LV Switchgear
(1) Pass type test. (TTA)
(2) Horizontal busbar located on upward side 01the cubicle
(3) The rated current of grade 3 or 4 horizontal busbar system could up to 7400
(4) Rated peak withstand current up to 375kA;
(5) Large depth dimensions of component compartment suitable for various mounting;
(6)The component compartment could be separated to different units according to modular structure;
(7)Single lace or back to back installation allowed ;
(8) Incoming way could be up- incoming or down - incoming
(9)Outgoing cable could be connected at front or rear cubicle
4. Notes for ordering for SIVACON 8PT Series LV Switchgear
While ordering, the users should supply the following documents:
1. All the type of the switchgear including the main circuit scheme number and the supplementary circuit scheme number.
2. The assembly sequence diagrams of the main circuit system
3. The electric principle diagram of the auxiliary circuit
4. The inner cubicle components list
5. The data of voltage, current, time in circuit
6. The special requirements not under the normal service condition.