XGN68-12 Series Switchgear XGN68-12(F), XGN68-12(F.R), XGN68-12(Z) Box Type (Indoor) AC Metal-clad Switchgear is the latest HV electrical complete set of equipment which is researched and manufactured by our company together with Beijing Electric Power Research Institution.
XGN68-12 Series Switchgear
XGN68-12 Series Switchgear is the smallest in the air insulated cabinet. It meets the environmental protection requirements for urban users and residential areas, and the effective floor area is the smallest.XGN68-12 Series Switchgear is the most ideal choice.
XGN68-12(F) Switchgear Parameters
|
Name |
Unit |
Parameters |
|
Rated Voltage |
kV |
12 |
|
Rated Frequency |
Hz |
50 |
|
Rated Current |
A |
630 |
|
Rated Short-time Withstand Current |
kA/s |
20/4 |
|
Rated Peak Withstand Current |
kA |
50 |
|
1min Power Frequency Voltage to Earth, Between Phases / Across the open gap (r.m.s) |
kV |
42/49 |
|
Lightning Impulse Withstand Voltage to Earth, Between Phases / Across the open gap (Peak) |
kV |
75/85 |
|
Secondary Circuit 1min Power Frequency Withstand Voltage |
kV |
2 |
|
Protection Class |
|
IP3X |
XGN68-12(F、R) Switchgear Parameters
|
Name |
Unit |
Parameters |
|
Rated Voltage |
kV |
12 |
|
Rated Frequency |
Hz |
50 |
|
Rated Current |
A |
125 |
|
Rated Transfer Current |
A |
3150 |
|
Rated Short-circuit Breaking Current |
kA |
31.5 |
|
Mechanical Life |
times |
2000 |
|
1min Power Frequency Voltage to Earth, Between Phases / Across the open gap (r.m.s) |
kV |
42/49 |
|
Lightning Impulse Withstand Voltage to Earth, Between Phases / Across the open gap (Peak) |
kV |
75/85 |
|
Secondary Circuit 1min Power Frequency Withstand Voltage |
kV |
2 |
|
Striker Capacity |
J |
2~5 |
|
Protection Class |
|
IP3X |
XGN68-12(Z) Switchgear Parameters
|
Name |
Unit |
Parameters |
|
Rated Voltage |
kV |
12 |
|
Rated Frequency |
Hz |
50 |
|
Rated Current |
A |
630 |
|
Rated Short-time Withstand Current |
kA/s |
20/4 |
|
Rated Peak Withstand Current |
kA |
50 |
|
Rated Shirt-circuit Breaking Current |
kA |
20 |
|
Rated Short-circuit Making Current (Peak) |
kA |
50 |
|
1min Power Frequency Voltage to Earth, Between Phases/ Across the open gap (r.m.s) |
kV |
42/49 |
|
Lightning Impulse Withstand Voltage to Earth, Between Phases / Across the open gap (Peak) |
kV |
75/85 |
|
1min Power Frequency Withstand Voltage of Secondary Circuit |
kV |
2 |
|
Protection Class |
IP |
3X |
g. It has small volume, only 50% volume of general switchgear.
6. Use place: no explosion risk, chemical corrosion, no violent vibration

XGN49-40.5 C-GIS Gas Insulation Cabinet Metal-clad Switchgear
KYN28A (KZN)-12KV Metal-Clad MID-Mount AC Switchgear
XGN75-12KV C-GIS Indoor Gas Insulation Metal-clad Switchgear
XGN58 (HXGT6A)-12 Indoor Gas Insulation Metal-clad Switchgear
XGN58 (HXGT6A)-24 Indoor Gas Insulation Metal-clad Switchgear
GFC-40.5KV C-GIS Gas Insulation Metal-clad Switchgear