Home > Products > Transformer > Oil-immersed Transformer > 110 kV Three Phase Oil Immersed Power Transformers
110 kV Three Phase Oil Immersed Power Transformers
  • Air Pro110 kV Three Phase Oil Immersed Power Transformers

110 kV Three Phase Oil Immersed Power Transformers

The design and technology of 110 kV Three Phase Oil Immersed Power Transformers in Tianan (group) are coming by summarizing and re-exploitation based on multifold and advanced technique. We combined the transformer production and design experiences in our company, the reliability and performance standard are all achieved international advanced level.

Send Inquiry

Product Description

1. Introduction of the 110 kV Three Phase Oil Immersed Power Transformers


This 110 kV Three Phase Oil Immersed Power Transformers can change power net voltage into the system or load voltage, achieving the delivery and distribution of power. This transformer product can be installed and used in outdoor or indoor condition, and it is an ideal equipment applied in the transmission and distribution network in factory, rural area and city.

 

 

2. Parameter of the 110 kV Three Phase Oil Immersed Power Transformers

 

S10 series 110kV double winding non-excitation tap-changing transformer

 

Type

Voltage and tap range

 

Connection

No-load loss

(kW)

Load loss

(kW)

No-load current

%

Impendence

%

Dimension

LxWxH mm

HV

LV

S(F)10-6300/110

 

 

 

 

 

 

 

 

110

115

121

132

±2

x2.5%

6.3

6.6

10.5

11

 

 

 

 

 

 

 

 

 

YNd11

8

34

0.65

 

 

 

 

 

 

 

 

10.5

4090 x 2980 x 4750

S(F)10-8000/110

9.5

42

0.65

4140 x 3020 x 4780

S(F)10-10000/110

11.2

48.5

0.64

4380 x 3080 x 4780

S(F)10-12500/110

12.1

59

0.55

4700 x 4200 x 5000

S(F)10-16000/110

16.0

73

0.5

3710 x 2880 x 4420

S(F)10-20000/110

18.5

86

0.5

5250 x 3937 x 4260

S(F)10-25000/110

21.3

98

0.5

5280 x 3980 x 4270

S(F)10-31500/110

24.2

120

0.47

5300 x 4060 x 4310

S(F)10-40000/110

29.3

139

0.47

5410 x 4150 x 4330

S(F)10-50000/110

36

180

0.5

5900 x 4380 x 6100

S(F)10-63000/110

40

217

0.5

6810 x 4520 x 5885

S(F)10-75000/110

48

246

0.5

5970 x 4600 x 6500

S(FP)10-75000/110

39.2

248

0.5

6420 x 4437 x 6356

S(FP)10-80000/110

51.9

273

0.5

6980 x 4390 x 6435

S(FP)10-90000/110

53.2

283

0.4

12440 x 5200 x 6700

S(FP)10-150000/110

15.75

79.2

420

0.4

9410 x 3450 x 6213

S(FP)10-240000/110

13.8

141

601

0.4

8500 x 5750 x 6400

 

 S10 series 110kV double winding on-load-tap-changing transformer

 

     Type

Voltage and tap range

Connection

No-load loss

(kW)

Load loss

(kW)

No-load current

%

Impendence

%

Dimension

L xW xH mm

HV

LV

S(F)Z10-6300/110

 

 

 

110

115

121

132

 ±8

 x

1.25%

 

 

 

6.3

6.6

10.5

11.

 

 

 

YNd11

8.5

35

0.55

 

 

 

 

 

 

 

 

10.5

4940 x 3710 x 4620

S(F)Z10-8000/110

10.5

43

0.55

5010 x 3770 x 4680

S(F)Z10-10000/110

12

50

0.55

5040 x 3810 x 4730

S(F)Z10-12500/110

14.5

59

0.55

5100 x 3870 x 4760

S(F)Z10-16000/110

16.4

70

0.5

5160 x 3900 x 4810

S(F)Z10-20000/110

18.9

86

0.5

5760 x 3780 x 4730

S(F)Z10-25000/110

22.6

101

0.5

5820 x 3840 x 4790

S(F)Z10-31500/110

26.4

117

0.45

6320 x 4035 x 5160

S(F)Z10-40000/110

32.6

142

0.4

6550 x 4670 x 5740

S(F)Z10-50000/110

34.6

179

0.4

6270 x 4560 x 5865

S(F)Z10-63000/110

39

217

0.4

6320 x 4610 x 5930

 

S10 series 110kV three winding non-excitation tap-changing transformer

Type

Voltage and tap range

 

Connection

No-load loss

(kW)

Load loss

(kW)

No-load current

%

Impendence

%

Dimension

 L xW xH mm

HV

MV

LV

Step up

Step down

S(F)S10-6300/110

110

115

121

132

± 2 X

2.5%

35

36.6

38.5

±2

 X

2.5%

6.3

6.6

10.5

11.0

 

 

 

 

 

 

 

 

 

 

YN

yn0

d11

9.5

45

0.7

 

HV- MV

17.5

 

 

 

 

 

HV-LV

10.5

 

 

 

 

MV-LV

6.5

 

 

 

 

 

HV- MV

10.5

 

 

 

 

 

HV-LV

17.5

 

 

 

 

MV-LV

6.5

4950 x 3320 x 3610

S(F)S10-8000/110

11.5

53

0.7

4970 x 3360 x 3640

S(F)S10-10000/110

13.5

62

0.7

5020 x 3410 x 3690

S(F)S10-12500/110

16

73

0.7

5080 x 3430 x 3740

S(F)S10-16000/110

18.6

87

0.7

5140 x 3490 x 3780

S(F)S10-20000/110

20.5

101

0.6

5300 x 3670 x 4200

S(F)S10-25000/110

23.1

119

0.6

6106 x 4877 x 4941

S(F)S10-31500/110

31.5

143

0.64

6060 x 4930 x 5010

S(F)S10-40000/110

36.4

174

0.6

7600 x 4300 x 5575

S(F)S10-50000/110

48

208

0.5

7680 x 4360 x 5640

S(FP)S10-63000/110

45.2

248

0.58

7850 x 4860 x 6020

S(FP)S10-75000/110

53.1

283

0.58

7800 x 4440 x 6610

 

 

3. Main Function and Features of the 110 kV Three Phases Oil Immersed Power Transformers


110kV Three Phases Oil Immersed Power Transformers

1

low loss, low noise, high reliability

2

Iron core is made of cold-rolled silicon-steel

3

Have good ability withstand short-circuit

4

The oil tank is bell type with the structure of full folding plate type,

5

Having an excellent exterior and easy for maintenance

6

Adopting capsule-type oil container, it can reduce oil aging to the lowest degree

7

Power loss: no-load loss is 30% lower than that of IEC standard

8

Reliability: All in-service product have no damages or oil leakage occurred

9

Convenient installation

 


4. Test equipment of 110 kV Three Phase Oil Immersed Power Transformers


Strict test should be done according to IEC standard, by high technical equipments to ensure the quality and the 110 kV Three Phase Oil Immersed Power Transformers

 


5. Qualification & certifications of 110 kV Three Phase Oil Immersed Power Transformers


 


6. Operation and maintenance of the 110 kV Three Phase Oil Immersed Power Transformers


◆After on-load operation for 24 hours(with 2 hours full-load), if the 110kV Three Phase Oil Immersed Power Transformer has no abnormal status, it can be put into operation.
◆A new 110kV Three Phase Oil Immersed Power Transformer has to be tested by gathering its oil sample for 5 times in its first operating month. The oil should be filtered if the withstand voltage value decreases too quickly. cover lifting check must be carried out if there are carbide in oil.
◆Normal operation & maintenance of 110 kV Three Phase Oil Immersed Power Transformers
◆Operation and maintenance should follow the《Operation Regulations of Power Transformer》of DL/T572-95 and the related stipulations from the Power Department.
◆At present, the 110 kV Three Phase Oil Immersed Power Transformers technology of our company adopted is the advanced technology in domestic. The transformer oil tank which adopt this technology can be taken as fully sealed structure and insure the service life of transformer belong to 30 years, maintenance-free.

 


7. FQA for the 110 kV Three Phase Oil Immersed Power Transformers

 

1) How do you pack the 110 kV Three Phase Oil Immersed Power Transformers?

By wooden case

 

2) What is your products standardization?

IEC and GB

 

3) How many years have your company made this kind of equipment?

More than 20years

 

4) What is the terms of payment?

L/C, T/T

 

5) What is your MOQ?

1set

 

6) How long is your delivery time?

60 working days

 

 

 

Hot Tags: 110 kV Three Phase Oil Immersed Power Transformers, China, Manufacturers, Suppliers, Factory, Made in China

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you within 24 hours.